A single pacemaker spike (marked by red lines) is followed by a P wave, normal PR interval, and normal QRS complex.
Graphic 82560 Version 3.0
Sinus rhythm
The normal P wave in sinus rhythm is slightly notched since activation of the right atrium precedes that of the left atrium. The P wave is upright in a positive direction in leads I and II. A P wave with a uniform morphology precedes each QRS complex. The rate is between 60 and 100 beats per minute and the cycle length is uniform between sequential P waves and QRS complexes. In addition, the P wave morphology and PR intervals are identical from beat to beat.