Oxygen flow settings for high-flow nasal cannula use in infants and children
Oxygen flow settings for high-flow nasal cannula use in infants and children
Patient weight
(kg)
Starting flow
(L/minute)
Maximum flow
(L/minute)
<5
6
8
5 to 10
8
15
10 to 20
15 to 20
20
20 to 40
25 to 30
40
>40
25 to 30
40 to 60
HFNC: high-flow nasal cannula.