Anesthesia machine |
- Checked, with circuit attached
|
Suction |
- Soft suction catheter for infants
|
- Yankauer for older children
|
- Two suction devices if large amounts of blood or emesis expected in the airway
|
Facemask |
- Sized to form seal around nose and mouth
|
Oxygen delivery system (if prolonged intubation predicted) |
- Standard nasal cannula, high flow nasal cannula, laryngoscope oxygen side port
|
Self-inflating reservoir bag |
- Backup in case of machine failure
|
Oral airway |
- Measured from corner of mouth to angle of mandible
|
Nasal airway |
- Measured from nare to earlobe, slightly smaller in diameter than nare
|
Laryngoscopes |
- Two, either in consecutive sizes (ie, Miller 1 and Miller 2), or one straight and one curved blade (ie, Miller 2 and Mac 2)
|
Endotracheal tubes |
- Correct cuffed tube size (ID in mm) predicted by 3.5 + (age in years/4)
|
- Have 0.5 mm smaller tube available
|
Stylets |
- Preloaded in ETT, or readily available
|
Supraglottic airway |
- Sized by weight, according to manufacturer's recommendation
|
Emergency drugs, drawn in syringes with needle appropriate for IM injection if no IV in place |
- Succinylcholine, 4 mg/kg for IM, 1 mg/kg for IV
|
- Atropine, 0.02 mg/kg for IM or IV
|