Journal of Refractive Surgery




One-year access to more than 500 world journals available in the system
    http://medilib.ir
  • Duration of Time : 365 Day
  • Price : 300$
  • Special Price : 100$
Order

Corneal Cross-linking at the Slit Lamp

Farhad Hafezi, MD, PhD, Olivier Richoz, MD, PhD, MBA, Emilio A. Torres-Netto, MD, Mark Hillen, PhD, and Nikki L. Hafezi, MAS IP ETHZ

doi : 10.3928/1081597X-20201123-02

Volume 37, Issue 2, February 2021, Published Online: November 23, 2020 | pp.78–82

PURPOSE:To describe a new surgical technique where corneal cross-linking (CXL) (to treat corneal ectasias) and photo-activated chromophore for keratitis-CXL (PACK-CXL) are performed while the patient is seated in an upright position at the slit lamp. ...

Buy The Package and View The Article Online


Mitomycin C Application After Corneal Cross-linking for Keratoconus Increases Stromal Haze

Shady T. Awwad, MD, Lily M. Chacra, MD, Chadi Helwe, MSc, Ahmad R. Dhaini, PhD, Talar Telvizian, MD, Julien Torbey, MD, Maamoun Abdul Fattah, MD, Emilio A. Torres-Netto, MD, Farhad Hafezi, MD, PhD, and Rohit Shetty, MD, PhD

doi : 10.3928/1081597X-20201124-01

Volume 37, Issue 2, February 2021, Published Online: November 24, 2020 | pp.83–90

PURPOSE:To evaluate and compare corneal haze as determined by optical coherence tomography (OCT) after corneal cross-linking (CXL) for the treatment of mild to moderate keratoconus with or without mitomycin C (MMC) application. METHODS:This was a ...

Buy The Package and View The Article Online


Two-Year Follow-up of Intracorneal Ring Segments Implantation in Adolescent Patients With Keratoconus

Cristina Peris-Mart?nez, MD, PhD, Mikhail Hern?ndez-D?az, MD, Maria José Roig-Revert, MD, PhD, Enrique Alfonso-Mu?oz, MD, Santiago Montol?o-Marzo, MD, and Daniel Mons?lvez-Rom?n, MD, PhD

doi : 10.3928/1081597X-20201123-03

Volume 37, Issue 2, February 2021, Published Online: November 23, 2020 | pp.91–97

PURPOSE:To evaluate the visual, refractive, topographic, and aberrometric outcomes after intracorneal ring segments (ICRS) implantation in adolescent patients with keratoconus. METHODS:A retrospective longitudinal study was undertaken with a total of 61 ...

Buy The Package and View The Article Online


Multifocal and Extended Depth of Focus Intraocular Lenses: A Comparison of Data from the United States Food and Drug Administration Premarket Approval Trials

Julie M. Schallhorn, MD

doi : 10.3928/1081597X-20201111-02

Volume 37, Issue 2, February 2021, Published Online: November 11, 2020 | pp.98–104

PURPOSE:To review and compare the results of unpublished premarket approval studies for recent multifocal and extended depth of focus (EDOF) intraocular lenses. METHODS:Lenses without previously published pre-market approval trials were identified and ...

Buy The Package and View The Article Online


Visual Outcomes and Patient Satisfaction After Bilateral Sequential Implantation of a Capsular Bag IOL and a Supplementary Sulcus-Fixated Trifocal IOL

Guenal Kahraman, MD, Nikolaus Dragostinoff, PhD, Wolfgang Brezna, PhD, Clemens Bernhart, MD, and Michael Amon, MD

doi : 10.3928/1081597X-20201215-01

Volume 37, Issue 2, February 2021, Published Online: December 15, 2020 | pp.105–111

PURPOSE:To assess visual and refractive outcomes and patient satisfaction after bilateral sequential implantation of a primary capsular bag intraocular lens (IOL) and a supplementary sulcus-fixated trifocal IOL. METHODS:All patients had bilateral ...

Buy The Package and View The Article Online


Rotational Stability of a New Hydrophobic Acrylic IOL With Modified C-loop Haptics

Daniel Schartmüller, MD, Veronika R?ggla, MD, Luca Schwarzenbacher, MD, Christina Leydolt, MD, and Rupert Menapace, MD

doi : 10.3928/1081597X-20201216-01

Volume 37, Issue 2, February 2021, Published Online: December 16, 2020 | pp.112–118

PURPOSE:To assess rotational stability, axial stability, decentration, and tilt of the Rayner RAO800C single-piece hydrophobic acrylic intraocular lens (IOL) (Rayner Intraocular Lenses Ltd) from end of surgery to 4 to 7 months postoperatively. METHODS:...

Buy The Package and View The Article Online


Phacoemulsification After Descemet Membrane Endothelial Keratoplasty: Incidence and Influence on Endothelial Cell Density

Indr? Vasiliauskait?, MSc, Sorcha N? Dhubhghaill, MB BCh, PhD, Lisanne Ham, PhD, Korine Van Dijk, PhD, Silke Oellerich, PhD, and Gerrit R. J. Melles, MD, PhD

doi : 10.3928/1081597X-20201208-01

Volume 37, Issue 2, February 2021, Published Online: December 8, 2020 | pp.119–125

PURPOSE:To analyze the incidence of cataract extraction after Descemet membrane endothelial keratoplasty (DMEK) in phakic eyes and to evaluate the effect of phacoemulsification after DMEK on the donor endothelial cell density (ECD). METHODS:The clinical ...

Buy The Package and View The Article Online


Long-term Outcomes and Complications of the New Carlevale Sutureless Scleral Fixation Posterior Chamber IOL

Agostino S. Vaiano, MD, PhD, Kenneth J. Hoffer, MD, Antonio Greco, MD, Andrea Greco, MD, Giovanni D'Amico, MD, Valerio Pasqualitto, MD, Carlo Carlevale, MD, and Giacomo Savini, MD

doi : 10.3928/1081597X-20201207-02

Volume 37, Issue 2, February 2021, Published Online: December 7, 2020 | pp.126–132

PURPOSE:To evaluate the visual outcomes and possible complications of a new foldable sutureless scleral fixation intraocular lens (SSF-IOL), the Carlevale IOL (Soleko). METHODS:The SSF-IOL, which has two T-shaped self-blocking plugs on each haptic, was ...

Buy The Package and View The Article Online


Agreement Between Angle-to-Angle Distance and Aqueous Depth Obtained With Two Different Optical Coherence Tomographers and a Scheimpflug Camera

Agreement Between Angle-to-Angle Distance and Aqueous Depth Obtained With Two Different Optical Coherence Tomographers and a Scheimpflug Camera

doi : 10.3928/1081597X-20201013-01

Volume 37, Issue 2, February 2021, Published Online: October 13, 2020 | pp.133–140

PURPOSE:To compare angle-to-angle (ATA) distance and aqueous depth (AQD) readings produced by two different optical coherence tomography (OCT) devices and a Scheimpflug camera. METHODS:ATA distance and AQD were measured in 60 eyes using the Visante time-...

Buy The Package and View The Article Online


Managing Suction Loss in SMILE

Sohini Mandal, MD, Manpreet Kaur, MD, and Jeewan S. Titiyal, MD

doi : 10.3928/1081597X-20210114-01

Volume 37, Issue 2, February 2021, Published Online: January 14, 2021 | pp.141

Buy The Package and View The Article Online


Erratum for “The Relationship Between Preoperative Anterior Corneal Higher Order Aberrations and Topography-Guided Excimer Ablation Depth”

doi : 10.3928/1081597X-20210112-01

Volume 37, Issue 2, February 2021, Published Online: January 12, 2021 | pp.144

Buy The Package and View The Article Online


Do you want to add Medilib to your home screen?